Products >   Dehumidify Unit
   


 


 



 


 

 


Name of resin
Initial moisture
%
Drying temperature
¡É
Drying time
Hr
Required moisture
%
Physical problems
Processed amount (kg/Hr)
Hydrolysis
SD-50
SD-100
SD-200
SD-300
SD-400
SD-800
SD-900
ABS
0.45
80
2~3
0.1~0.07
-
-
47
71
100
143
296
418
535
PC
(General type)
0.3
120~130
1.5~2
0.03~0.02
¡Û
-
60
91
127
182
377
532
682
PC
(For disk)
0.18
120~130
1.5~2
0.01~0.005
¡Û
-
60
91
127
182
377
532
682
POM
0.3
80~90
1.5~2
0.02~0.01
-
-
47
71
100
143
296
418
535
PPO
0.1~0.2
120
1~2
0.07
-
-
52
78
109
156
324
457
586
PP+TALC
0.16
120
2
0.05
-
-
67
100
140
200
415
585
750
AS
0.2~0.3
80
2~3
0.07
-
-
52
75
109
156
324
457
586
PMMA
(General type)
0.4
80
3
0.07~0.05
-
-
40
60
85
121
252
355
455
PMMA
(For disk)
0.2
80
2~3
0.02~0.01
-
-
40
60
85
121
252
355
455
PA6, 66
0.5
80
4~6
~
¡Û
Oxidation discoloration
Please ask for information separately when nylon is used.
PBT
0.25
130
2
0.02
¡Û
-
27
40
56
80
166
234
300
PET
(For bottle)
0.35
160(140)
2.5~3(3~4)
0.005~0.003
¡Û
-
27
40
56
80
166
234
300
PET
(For filament)
0.4
150
2.5~3
0.01~0.007
¡Û
-
27
40
56
80
166
234
300


* The numerical values are changed a little bit according to the resin grade, physical nature, and drying condition, etc..


 

   

Form
Frequency
For the use of heater for drying
Wind tunnel for drying
Regeneration blower
Capacity of regenerated heater
(Kw)
Required flow rate of after cooler
(§¤/min)
Outer standard
Hopper for drying the object (standard)
Standard
(Kw)
High temperature
(Kw)
Output of motor
(Kw)
Output of motor
(Kw)
Crossways
(§®)
Length
(§®)
Height
(§®)
Weight
(§¸)
SS UM-80
60Hz
2.4
4.0
0.42
0.12
2.4
6
650
702
1300
155
KE-25, 50R
SS UM-120
60Hz
3.3
6.0
0.85
0.28
3.0
10
167
KE-75,100R
SS UM-170
60Hz
4.0
7.8
0.75
0.15
5.8
17.5
800
1002
1800
370
KE-150,200R
SS UM-240
60Hz
6.0
12.4
1.5
0.2
9.0
25
355
KE-250,300R
SS UM-500
60Hz
12.4
23.0
2.2
0.28
13.8
50
1100
1450
2200
-
KE-400,500R
SS UM-700
60Hz
18.0
30.0
3.7
0.3
18.3
75
-
KE-700R
SS UM-900
60Hz
24.0
40.0
5.5
0.75
21.0
100
1450
1450
2603
-
KE-900,1100R

* Temperature of water in the cooling tower is 32¡É
* The hopper for drying the object can be changed according to the object that is dried.
* The specification can be changed without notice, for improving products.

 

 



copyright